M800VS/M80V Series Connection and Setup Manual
4 General Specifications
4.8 Operation Panel I/O Unit
69
IB-1501613-A
4.8 Operation Panel I/O Unit
4.8.1 List of Units
(*1) The form of the CG31/CG32/CG35/CG36 connectors on FCU8-DX731 are the same as that of CJ38/CJ40/CJ42 con-
nectors on other units. Be careful not to connect to a wrong connector. See the descriptions mentioned in the later sec-
tion for more specific explanation on connections.
(*2) The connection method of DO (CG32/CG34) of FCU8-DX834 is different from other operation panel I/O units. Be careful
not to connect to a wrong connector. See the descriptions mentioned in the later section for more specific explanation on
connections.
Classification Type Components Remarks
DI 24 V/0 V common input [64
points]
DO Source output [48 points]
AO analog output [1 point]
FCU8-DX731 (*1)
Base card
RIO 2.0 terminator connector (R2-TM)
DI: 64-points 24 V/0 V common type
DO: 48-points source type (200 mA/point)
AO: 1 point
Manual pulse generator input: 2 ch
Control unit I/F
Keyboard unit I/F
Remote I/O 2.0 I/F
RIO occupied stations (fixed):
1, 3, 7 to 12, 20 to 22
RIO extensible stations:
2, 4 to 6, 13 to 19, 23 to 64
DI 24 V/0 V common input [96
points]
DO Source output [64 points]
FCU8-DX750
Base card
RIO 2.0 terminator connector (R2-TM)
DI: 96-points 24 V/0 V common type
DO: 64-points source type (200 mA/point)
Manual pulse generator input: 3 ch
Control unit I/F
Keyboard unit I/F
Remote I/O 2.0 I/F
RIO occupied stations (fixed):
1 to 3, 7 to 12, 20 to 22
RIO extensible stations:
4 to 6, 13 to 19, 23 to 64
DI 24 V/0 V common input [96
points]
DO Source output [96 points]
FCU8-DX760
Base card
Add-on card
RIO 2.0 terminator connector (R2-TM)
DI: 96-points 24 V/0 V common type
DO: 96-points source type (200 mA/point)
Manual pulse generator input: 3 ch
Control unit I/F
Keyboard unit I/F
Remote I/O 2.0 I/F
RIO occupied stations (fixed):
1 to 4, 7 to 12, 20 to 22
RIO extensible stations:
5, 6, 13 to 19, 23 to 64
DI 24 V/0 V common input [96
points]
DO Source output [64 points]
AI Analog input [1 point]
AO Analog output [1 point]
FCU8-DX761
Base card
Add-on card
RIO 2.0 terminator connector (R2-TM)
DI: 96-points 24 V/0 V common type
DO: 64-points source type (200 mA/point)
AI: 1 points
AO: 1 point
Manual pulse generator input: 3 ch
Control unit I/F
Keyboard unit I/F
Remote I/O 2.0 I/F
RIO occupied stations (fixed):
1 to 5, 7 to 12, 20 to 22
RIO extensible stations:
6, 13 to 19, 23 to 64
DI 24 V/0 V common input [64
points]
DO Source output [64 points]
Scan input [64 points]
Scan output [64 points]
FCU8-DX834 (*2)
Base card
Add-on card
RIO 2.0 terminator connector (R2-TM)
DI: 64-points 24 V/0 V common type
DO: 64-points source type (200 mA/point)
Scan input: 64 points
Scan output: 64 points
Manual pulse generator input: 3 ch
Keyboard unit I/F
Remote I/O 2.0 I/F
RIO occupied stations (fixed):
1 to 4, 7 to 14, 20 to 22
RIO extensible stations:
5, 6, 15 to 19, 23 to 64