M800VS/M80V Series Connection and Setup Manual
19 Setting the Parameters and Date/Time
19.3 Setting the Parameters for the Machine Specifications
418
IB-1501613-A
19.3 Setting the Parameters for the Machine Specifications
(1) On the Mainte screen, select [Mainte] and then [Psswd input]. Enter the machine parameter password in the setting area
and press the [INPUT] key.
To enter the character "A", press the shift key and then "A" key. Do not press both keys at the same time.
(2) Go back to the Mainte screen. Then select [Param].
Set the parameters according to the machine specifications. Setting of the following parameters is necessary.
[Base system parameters]
"#1025 I_plane" (Initial plane selection)
"#1026 base_I x" (Initial plane selection)
"#1027 base_J" (Base axis J)
"#1028 base_K" (Base axis K)
"#1029 aux_I" (Flat axis I)
"#1030 aux_J" (Flat axisJ)
"#1031 aux_K" (Flat axis K)
[Base axis specification parameters]
"#1603 PLCdev_no (Axis device assignment No.)"
Set this in one of the following cases:
- When the system has five or more part systems
- When the part system has nine or more axes
- When you want to change the assignment of axis device
[Device]
The device Nos corresponding to (1) to (32) differ depending on device type.
Part system 1 Part system 2 Part system 3 Part system 4
(1) (9) (17) (25) Axis 1
(2) (10) (18) (26) Axis 2
(3) (11) (19) (27) Axis 3
(4) (12) (20) (28) Axis 4
(5) (13) (21) (29) Axis 5
(6) (14) (22) (30) Axis 6
(7) (15) (23) (31) Axis 7
(8) (16) (24) (32) Axis 8
Note
Note