M800VS/M80V Series Connection and Setup Manual
32 Adjust S-analog Screen
32.3 Performing Manual Adjustments
560
IB-1501613-A
32.3 Performing Manual Adjustments
Adjusting the ch0 0 V offset
(1) Use the [ ] [ ] keys to move the cursor to
"#10101", then press [Manual adjust].
The current setting value is displayed under "Current adjust
data".
A 0 V analog voltage is output to ch0 at this time.
(2)
Monitor the analog voltage. Adjust the 0 V offset until the analog voltage is 0 V ±3.5 mV.
The setting range -999 to 999.
(3)
<For plus-voltage>
Press [Voltage -1] or [Voltage -10]. "Current adjust data" is adjusted downward in decrements
of 1 each time [Voltage -1] is pressed.
"Current adjust data" is adjusted downward in decrements
of 10 each time [Voltage -10] is pressed.
<For minus-voltage>
Press the menu [Voltage +1] or [Voltage +10]. "Current adjust data" is adjusted upward in increments of 1
each time [Voltage +1] is pressed.
"Current adjust data" is adjusted upward in increments of
+10 each time [Voltage 10] is pressed.
<Note>
The range for "current adjust data" is -999 to 999.
The adjustments cannot exceed this range.
(4)
Press the [INPUT] key. "Current adjust data" will be set to "ch0 0 V offset", and the
0 V offset result in enabled.
Adjusting the ch0 + gain
(1) Use the [ ] [ ] keys to move the cursor to
"#10102", then press [Manual adjust].
The current setting value is displayed under "Current adjust
data".
A +10 V analog voltage of ch0 is output at this time.
(2)
Monitor the analog voltage. Adjust the + gain until the monitor voltage is 10 V ±3.5 mV.
The setting range -999 to 999.
(3)
<For 10 V or higher>
Press the menu [Voltage -1] or [Voltage -10]
<For less than 10 V>
Press the menu [Voltage +1] or [Voltage +10].
(4)
Press the [INPUT] key. "Current adjust data" will be set to "ch0 + gain", and the ad-
justment result is enabled.