M800VS/M80V Series Connection and Setup Manual
23 Setting the Tool Entry Prohibited Range
23.2 Stored Stroke Limit
467
IB-1501613-A
23.2 Stored Stroke Limit
23.2.1 Outline
Three tool entry prohibited ranges can be set with stored stroke limit I, stored stroke limit II (or IIB), and stored stroke limit IB.
Part of the prohibited range on the outside of stored stroke limit I can turn into a moveable range with stored stroke limit IC.
Set the parameters to select the entry prohibited range, stored stroke limit II or IIB.
(II: Prohibits entering outside the range IIB: Prohibits entering inside the range)
: Moveable range
: Prohibited range
(A): Prohibited range by stored stroke limit I
(B): Prohibited range by stored stroke limit IIB
(C): Prohibited range by stored stroke limit IB
(D): Moveable range by stored stroke limit IC
If the axis is moving over the set range, an alarm will appear and the axis will decelerate to a stop.
If the prohibited range is entered and an alarm occurs, movement will be possible only in the direction opposite the entry
direction.
(B)
(C)
(A)
(D)