M800VS/M80V Series Connection and Setup Manual
23 Setting the Tool Entry Prohibited Range
23.2 Stored Stroke Limit
472
IB-1501613-A
23.2.4 Stored Stroke Limit IB
Boundaries are set for each axis with the axis parameters "#2061 OT_1B-" and "#2062 OT_1B+". The inside of the set
boundary is the prohibited range.
: Moveable range
: Prohibited range
Positions No. 5 "#2062 OT_1B+ (Soft limit IB+)" and No. 6 "#2061 OT_1B- (Soft limit IB-)" are set using coordinates from the
basic machine coordinate system.
(A): Set value for (-) side
(B): Set value for (+) side
(C): Prohibited range by stored stroke limit II
(D): Prohibited range by stored stroke limit IB
Positions No. 1 and 2 define the prohibited range as set with stored stroke limit I, and Positions No. 3 and 4 define the
prohibited range as set with stored stroke limit IIB.
3
4
5
6
(B)
(A)
(C)
(D)
2
1