17 Setting the Hardware
17.6 Connecting and Setting the Remote I/O Unit
402
IB-1501613-A
17.6.5 Thermistor Input Interface
By connecting the remote I/O unit with thermistor, up to 12 points of thermistor input are available.
For details on units with the thermistor input function, refer to "4.9 Remote I/O Unit".
Up to 12 points of the thermistor are detected in the ascending order of the channel No. and station No. of the remote I/O
unit. The file registers outputting temperature information are assigned inputs (thermistor input n (TIn)) but are not assigned
to the 13th or later thermistor input. The relationship between thermistor inputs and file registers is as follows:
[PLC input signals]
Through the interface you can read the temperature sensed by a thermistor connected to the designated connector of
thermistor input-equipped remote I/O unit.
Channel File register Data update cycle
TI0 ZR13028 The thermistor voltage acquired with the thermistor input-equipped re-
mote I/O unit is input after converted to a temperature value per PLC me-
dium-speed cycle.
One station of remote I/O has 4 thermistor inputs, thus 4 PLC medium-
speed cycles are required for the inputs of one station.
TI1 ZR13029
TI2 ZR13030
TI3 ZR13031
TI4 ZR13032
TI5 ZR13033
TI6 ZR13034
TI7 ZR13035
TI8 ZR13036
TI9 ZR13037
TI10 ZR13038
TI11 ZR13039