M800VS/M80V Series Connection and Setup Manual
3 List of Configuration
3.7 Operation Panel I/O Unit
12
IB-1501613-A
3.7 Operation Panel I/O Unit
DI: Digital input signals, DO: Digital output signals
Classification Type Components Remarks
DI 24 V/0 V common input [64
points]
DO Source output [48 points]
AO analog output [1 point]
FCU8-DX731
Base card
RIO 2.0 terminator connector (R2-TM)
DI: 64-points 24 V/0 V common type
DO: 48-points source type (200 mA/
point)
AO: 1 point
Manual pulse generator input: 2 ch
Control unit I/F
Keyboard unit I/F
Remote I/O 2.0 I/F
RIO occupied stations (fixed):
1, 3, 7 to 12, 20 to 22
RIO extensible stations:
2, 4 to 6, 13 to 19, 23 to 64
DI 24 V/0 V common input [96
points]
DO Source output [64 points]
FCU8-DX750
Base card
RIO 2.0 terminator connector (R2-TM)
DI: 96-points 24 V/0 V common type
DO: 64-points source type (200 mA/
point)
Manual pulse generator input: 3 ch
Control unit I/F
Keyboard unit I/F
Remote I/O 2.0 I/F
RIO occupied stations (fixed):
1 to 3, 7 to 12, 20 to 22
RIO extensible stations:
4 to 6, 13 to 19, 23 to 64
DI 24 V/0 V common input [96
points]
DO Source output [96 points]
FCU8-DX760
Base card
Add-on card
RIO 2.0 terminator connector (R2-TM)
DI: 96-points 24 V/0 V common type
DO: 96-points source type (200 mA/
point)
Manual pulse generator input: 3 ch
Control unit I/F
Keyboard unit I/F
Remote I/O 2.0 I/F
RIO occupied stations (fixed):
1 to 4, 7 to 12, 20 to 22
RIO extensible stations:
5, 6, 13 to 19, 23 to 64
DI 24 V/0 V common input [96
points]
DO Source output [64 points]
AI Analog input [1 point]
AO Analog output [1 point]
FCU8-DX761
Base card
Add-on card
RIO 2.0 terminator connector (R2-TM)
DI: 96-points 24 V/0 V common type
DO: 64-points source type (200 mA/
point)
AI: 1 points
AO: 1 point
Manual pulse generator input: 3 ch
Control unit I/F
Keyboard unit I/F
Remote I/O 2.0 I/F
RIO occupied stations (fixed):
1 to 5, 7 to 12, 20 to 22
RIO extensible stations:
6, 13 to 19, 23 to 64
DI 24 V/0 V common input [64
points]
DO Source output [64 points]
Scan input [64 points]
Scan output [64 points]
FCU8-DX834
Base card
Add-on card
RIO 2.0 terminator connector (R2-TM)
DI: 64-points 24 V/0 V common type
DO: 64-points source type (200 mA/
point)
Scan input: 64 points
Scan output: 64 points
Manual pulse generator input: 3ch
Keyboard unit I/F
Remote I/O 2.0 I/F
RIO occupied stations (fixed):
1 to 4, 7 to 14, 20 to 22
RIO extensible stations:
5, 6, 15 to 19, 23 to 64

Table of Contents