9 CREATING A HARDWARE LOGIC
9.2 Multi Function Counter Block
131
9
Link combination
An input terminal and output terminal in the same color can be linked among the internal blocks. Input terminals or output
terminals cannot be linked each other.
The following table lists the combinations.
*1 The terminals are linked by default. The links cannot be deleted.
*2 The terminals can be linked when a 16-bit multi function counter block is used. They cannot be linked when a 32-bit multi function
counter block is used.
If multiple output terminals are linked to one input terminal, OR processing is executed on all input signals. If one output
terminal is linked to multiple input terminals, the same signals are output for all the input terminals.
Output side Input side Color
Block name Terminal name Block name Terminal name
Input terminal Input Input signal event detection block Input
*1
Coral
Latch input terminal Latch Latch event detection block Input
*1
Pale orange
Event input terminal Event Counter timer block RUN Butterfly yellow
STOP
UP
DOWN
PRESET
Latch
Input signal event detection block Output Counter timer block RUN Hop green
STOP
UP
DOWN
PRESET
Set/reset block Set
Reset
Output terminal Output
Event output terminal Event
*2
Latch event detection block Output Counter timer block Latch
*1
Celadon
Counter timer block Count Value Comparison block Input
*1
Cyan blue
Cam switch block Input
*1
Comparison block Output Set/reset block Set Vermeer
Reset
Event output terminal Event
Cam switch block Output Cam switch output terminal Cam Output
*1
Columbine blue
Set/reset block Output Output terminal Output Lilac