2.7 Operating Environment
DANGER
USING THE EQUIPMENTIN AN ENVIRONMENT FOR WHICH ITIS NOT
DESIGNED CAN BE DANGEROUS. IT WILLALS0 REDUCE THE
EQUIPMENT'S LIFETIME ANDINCREASE THE MAINTENANCE
REQUIREMENTS.
If the operating environment deviates from the environment specified when the product was
ordered, contact the manufacturer. Solutions are available to enable the product to work in a
wide range of operating environments. If the product for general use would be used in
exceptional ambient conditions or for handling dangerous substances, consult the
manufacturer or manufacturer's representative. Notice, for example, that molten metal is
considered a dangerous substance. Examples of exceptional ambient conditions include windy
areas, earthquake zones and corrosive atmospheres.
The product designed for general use may be used in normal industrial environments which
fulfill the following conditions.
Indoor products must be situated indoors, protected from outdoor weather conditions.
Ambient temperature is specified in the order confirmation. Typically it is between-20(-4
) and +40(104 ) or +50(122 ).
Air quality meets the requirements of the EN standard 14611-1 1999.
The product is not exposed to any corrosive chemicals or an explosive atmosphere.
The product is not located in an area prone to earthquakes.
The product is less than1000 m(3280 feet) above sea level.
Relative air humidity must not exceed90%.
Note: There can be extra optional features in your equipment to allow
operation in special environments such as outdoors. In case of doubt please
contact your manufacturer or manufacturer's representative.
2.8 Safety During Installation
1
Ensure the competence of installation personnel
0wners SHALL ensure that installation personnel are professionally
competent, professionally qualified and are provided with adequate
instructions for carrying out the work.
2
Ensure proper commissioning and handover
Owners SHALL ensure that the test loading, test drive and
commissioning inspection have been property executed and that
the handover log has been properly completed.
Owners SHALL ensure that components, electrical connections
and steel structures of the product have beef1 inspected and
certified as defect-free.

Table of Contents