Appendix
09/01 AWB8230-1412GB
110
Digital control inputs programmable as FWD: Start/stop clockwise rotation
REV: Start/stop anticlockwise rotation
FF1 to FF4: Fixed frequency selection
JOG: Jog mode
AT: Use setpoint value 4 to 20 mA
2CH: Second time ramp
FRS: Free run stop
EXT: External fault message
USP: Restart inhibit
RST: Reset
SFT: Software protection
PTC: PTC thermistor input
Outputs
Digital signalling inputs programmable as FA1/FA2: Frequency achieved/exceeded
OL: Overload
AL: Fault
RUN: Motor operational
OD: PID deviation exceeded
Monitoring of frequency and current
Connection of an analog display device: 0 to 10 V H, maximum 1 mA for frequency
or current
Connection of a digital frequency meter
Signalling relay
Relay contact as a two-way switch; relay energized with a fault
Further features (excerpt)
Automatic voltage regulation
Restart inhibit
Variable amplification and output voltage reduction
Frequency jumps
Minimum/maximum frequency limitation
Output frequency display
Fault history register available
Freely selectable carrier frequency: 0.5 to 16 kHz
PID closed loop control
Automatic torque boost
Safety features
Overcurrent
Overvoltage
Undervoltage
Overtemperature
Ground fault
Overload
Electronic motor protection
Ambient conditions
Ambient temperature 10 to +50 °C
From about +40 to +50 °C, the carrier frequency should be reduced to 2 kHz.
The output current should be less than 80 % of the rated current in this case.
Temperature/humidity during storage
25 to 70 °C (for short periods only, e.g. during transport)
20 to 90 % relative humidity (non condensing)
Permissible vibration
Maximum 5.9 m/s
2
(= 0.6 g) at 10 to 55 Hz
Installation height and location
Maximum 1000 m above sea level in a housing or control panel (IP54 or similar)
Optional accessories
DEX-KEY-10 remote operating unit
Choke to improve the power factor
RFI filter
Weight in kg (approx.)
1.3 1.7 2.8 5.5 5.7
DF5-340-...
037 075 1K5 2K2 3K0 4K0 5K5 7K5