154 | Section 4 Appliances ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ ----------------- Monarch SE 2004
• The refrigerator operates from LP-Gas or 120 Volts AC electric.
• DC Voltage must be no higher than 15.4 Volts DC or lower than 10.5 Volts DC.
• AC voltage must be no higher than 132 Volts AC or lower than 108 Volts AC.
• It is important to operate the refrigerator only when level. Level the refrigerator
(from front view) within 3º side to side and 6º front to back using a torpedo
or bulls eye (fence post) level. Place the level on the freezer plate. The
level should be within the circle by a half of a bubble. Generally, this is
within comfortable living conditions.
NOTE: Operating the refrigerator "off level" separates the chemicals,
causing them to crystallize and block the circulation action of the
cooling unit. Damage is cumulative and irreversible.
WARNING: Do not use the refrigerator if there is an ammonia smell
inside or outside of the refrigerator, or if a yellowish substance appears
inside or at the outside access compartment. This can be an indication of
a refrigerant leak. Contact an authorized repair facility.
NOTE: To reduce the possibility of food spoilage, keep the interior box
temperature at or below 54º F. The refrigerator will consume more energy
to maintain low temperature, especially in hot, humid climates. Lower
temperature may also lead to quicker frost build-up.
In order for the refrigerator to operate:
• The house batteries must be charged.
• The primary LP-Gas valve must be on and the electric gas valve must be
on.
• Figure A: The refrigerator AC cord(s) must be plugged in
(located outside behind refrigerator access door).
• Figure B: The water valve must be on if the refrigerator is equipped
with an icemaker.
• Figure C: If the controls do not light up check the house batteries
charge status or see if the 12 Volt wires are plugged into the refrigera-
tor's circuit board (located outside behind refrigerator access door).