Monarch SE 2004-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- Section 4 Appliances | 179
• To conserve LP-Gas, turn off the water heater when not in use.
• When using the shower, conserve energy and hot water by shutting
the shower water off when not in use.
• Use caution when hooked to anything less than 50 Amp shore service.
When the water heater element is in operation it will use approximately
12 AC Amps. Appliances will need to be operated in sequence to
avoid tripping a breaker.
• Water may drip occasionally from the Temperature-Pressure relief
valve until the pressure has dropped. Avoid opening the T & P
valve manually as collected minerals may cause the valve to leak
continually. The valves can be purchased from most hardware
stores.
• Operate the water heater using LP-Gas when hooked to 30 Amp
shore power. This will reduce the likelihood of tripping the shore
power breaker.
If the motorhome is to be stored during the winter months, drain the water
heater to prevent freeze damage.
1. Turn off electrical power to the water heater.
2. Shut off the primary LP-Gas valve.
3. Open low point drains.
4. Open both HOT and COLD on all faucets.
5. Remove water heater drain plug.
6. Turn the Bypass lever to BYPASS.
NOTE: Be sure to refill the water heater with water before
resuming operation.
Troubleshooting
• If water heater fails to light check the mixture tube for obstructions.
Spiders may make nests in the burner tube. It is recommended by
cleaning the burner tube with a brush and not compressed air.
Compressed air may not fully remove the obstruction.
• If the indicator light on the switch does not light, and the water heater
does not light, ensure the house power switch at the entry door is on
or check for a blown fuse in the house distribution panel.
• If the water heater fails to operate after checking the fuses, the High
Temperature safety limit switch may be tripped. Have a qualified
technician inspect the water heater.
Tips
Draining & Storage