To start generator:
1. Push and hold control switch in START position until the generator
starts.
2. Release switch.
Warning: Excessive cranking can overheat and damage the
starter motor. Do not crank the engine more than thirty seconds
at any one time. Wait at least two minutes before resuming.
INFORMATION: If the generator fails to start refer to the
generator manufacturer's owner's manual.
WARNING: When the motorhome is parked, position the dash
air conditioner vent control in the OFF position to prevent
exhaust gases from entering the motorhome. The engine exhaust
contains carbon monoxide, which is an odorless and colorless
gas. Carbon monoxide is poisonous and can cause
unconsciousness and/or death. Inspect the exhaust system
thoroughly before starting the generator. Do not block the
exhaust pipe or situate the motorhome where the exhaust may
accumulate either outside, underneath, or inside the motorhome
or any nearby vehicles. Operate the generator only when safe
dispersion of exhaust can be assured. Monitor the outside
conditions to be sure that the exhaust continues to disperse
safely.
WARNING: When parking, be aware of area around generator.
The hot exhaust or exhaust gases may ignite dry grass or other
flammable materials.
CAUTION: An exhaust extension adds weight and stresses the
generator exhaust system. Damage to the exhaust piping or
exhaust manifold can result, allowing carbon monoxide gases to
accumulate under or leak into the motorhome.
Turn off the appliances and other AC loads being used.
Allow the generator to run unloaded for at least one minute
before shutdown. This will allow the engine to cool.
Momentarily press the control switch to the STOP.
Starting the Generator
Stopping the
Generator
080357
080357