Monarch SE 2004-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- Section 8 Electrical System | 285
Electrical Adapters:
There are many different electrical adapters available to suit a variety of needs.
Only UL approved adapters should be used. The most common adapter is a 50-30
Amp adapter. The type of connector adapts the 50 Amp shore cord to a 30 Amp
shore power outlet. Always install the adapter to the cord prior to making the
connection to the outlet.
Another common adapter is a 30 to 20 Amp adapter. This type of connector
adapts the 30 Amp shore cord to a 20 Amp shore power outlet.
CAUTION: If shore power service is limited to 15 or 20 Amps,
use of light duty extension cords and electrical adapters will
create a voltage loss through the cord and at each electrical
connection. Line voltage loss and the resistance at each electrical
connection can be a hazardous combination. Damage to sensitive
electronic equipment may result!
CAUTION: Avoid the risk of electrical shock or component
damage by disconnecting from shore power during electrical
storm activity. Use the inverter or start the generator if AC
power is needed.