4-12
Leased Line Option
This option supports both 2 and 4 wire connections.
• Two-Wire Line Connection (See Figure 4-8)
1. Set both switches of dip switch 2W / 4W SELECT on the Line Interface Unit’s front
panel to position 2W.
2. There are two options to connect the line wire to the Line Interface Unit:
– If the telephone line has an RJ11 connector plug it into the 2-WIRE LINE connector on
the unit’s front panel.
Or:
– If the telephone line does not have an RJ11 connector connect the wires to terminals #1
and #2 of the unit’s front panel TB. The polarity is insignificant.
Figure 4-8 2W Leased Line Option - Electrical Connections
PRO
GND
2W
T
/Rx Lease
Line
To
2W
T
/ Rx Leased Lin
Optional Telephon e Cable
with RJ11 Connectors
Dip Switch
2W position