5.10 READ
ERRORS-ALL
TRACKS
A.
Verify
that
head
is
loaded
by
visually
checking
that
head
load
pad
(or
upper
head
on Model
42)
contacts
diskette.
If
head
is
not
loaded
refer
to
paragraph
5.6.
B. Check
compliance
(refer
to
paragraph
4.
7
.1).
If
compliance
is
bad,
clean
head
and/or
replace
load
pad
assembly
((refer
to
paragraph
4.5.18).
C.
Check
read
logic
for
proper
signals
as
compared
with
timing
diagram,
Figure
3-6.
D.
Check
for
a
poor
connection
or
a
broken
wire
on
the
head
cable(s).
E.
Replace
the
Control
Electronics
PCBA.
If
there
still
is
no
read
signals
from
the
drive,
replace
the
head/carriage
assembly
(refer
to
paragraph
4.5.10).
5.11
READ
ERRORS-RANDOM
TRACKS
A.
Check
for
an
intermittent
connection
of
the
read/write
head
connector.
B.
Replace
the
Control
Electronics
PCBA
(refer
to
paragraph
4.5.1).
C.
Replace
the
Spindle
Speed
Control
PCBA
(refer
to
paragraph
4.5.1).
D.
Replace
the
spindle
drive
motor
(refer
to
paragraph
4.5.7).
5.12 READ
ERRORS-INSIDE
TRACKS
A.
Check
compliance
(refer
to
paragraph
4.
7
.1).
If
compliance
is
bad,
replace
load
pad
assembly
(refer
to
paragraph
4.5.12),
and/or
clean
head.
B. Check
erase
capability
(refer
to
paragraph
4.7.2).
If
erase
is
bad,
see
paragraph
5.15.
c. Check
high
frequency
output
(refer
to
paragraph
4.7.3).
If
output
is
bad,
replace
the
head/carriage
assembly
(refer
to
paragraph
4.5.10).
5.13
CANNOT
READ PREWRITTEN DATA: CAN READ SELF-WRITTEN DATA
A.
Check
radial-track
alignment
(refer
to
paragraph
4.6.1).
B. Check
index-to-data
alignment
(refer
to
paragraph
4.6.2).
5-4