Annular light
The annular light indicates the status of the RF module during operation:
Yellow flashing light:
Normal mode, full RF power.
Red flashing light:
Reduced transmitting power for the range check (see page 47).
Rapidly flashing orange light:
Device in binding mode (see page 48).
Steady yellow light:
No RF signal is emitted; a PC or battery charger is connected. Battery
charging in progress. The power is supplied by the battery charger.
Steady red light:
No RF signal is emitted; a PC or battery charger is connected. The battery is
charged and does not need charging. The battery runs down as the power is
drawn from it. Once the charge has dropped to 98%, the charging circuit is
switched on again.
Warning lights
The warning lights serve as markers for the sensor alarms.
The following warning lights are assigned to the sensors:
Battery icon: all voltage sensors
Thermometer: all temperature sensors
Petrol pump: all sensors for fuel status and battery charge
IC icon: ECU (Engine Control Unit)
Warning sign: all sensors for speed, power, reception quality
(LQI = Link Quality Indication)
Press the ENTER button to clear the warning bar if status display #2 is shown.
It is also possible to assign a switch to clear the warning lights and mute the sensor
alarm (see "Assigning switches" on page 171).