Electra Elite IPK II Document Revision 1
Barge-In 2 - 79
Programming
11-12-08 Service Code Setup (for Service Access) - Barge-In
Determine what the service code should be for an internal party to use the Barge-In feature
(default = 710).
11-16-02 One-Digit Service Code Setup - Barge-In
Use this option to set up Item 02 for single digit Barge-In. For example, you can assign Item 02
to use digit 5 for Barge-In. This would allow you to program a function key with an extension
number plus the Barge-In code (i.e., 5). This allows one-touch access to the Barge-In feature for
extension.
15-07-01 Programming Function Keys
Assign a function key for Barge-In (code 34).
20-06-01 Class of Service for Extensions
Assign a Class of Service (1~15) to an extension.
20-13-10 Class of Service Options (Supplementary Service) - Barge-In Mode
For extension’s Class of Service, enable the Barge-In Speech Mode (0) or Monitor Mode (1) at
the initiating extension (i.e., Barge-In initiator).
20-13-15 Class of Service Options (Supplementary Service) - Barge-In, Initiate
In an extension’s Class of Service, enable (1) or disable (0) Barge-In at the initiating extension
(i.e., Barge-In initiator).
20-13-16 Class of Service Options (Supplementary Service) - Barge-In, Receive
In an extension’s Class of Service, enable (1) or disable (0) Barge-In at the receiving extension
(i.e., Barge-In receive).
20-13-17 Class of Service Options (Supplementary Service) - Barge-In Tone/Display
In an extension’s Class of Service, enable (1) or disable (0) the Barge-In (Intrusion) Tone. If
disabled, this also turns off the Barge-In display at the called extension.
20-13-32 Class of Service Options (Supplementary Service) - Multiple Barge-In
In an extension’s Class of Service, enable (1) or disable (0) the extension’s ability to have
multiple user’s Barge-In to their conversation.
20-14-11 Class of Service Options for DISA/E&M - DISA/Tie Trunk Barge-In
In an extension’s Class of Service, enable (1) or disable (0) a DISA or tie trunk user from using
the Barge-In feature with the service code defined in Program 11-12-08.
20-18-07 Service Tone Timer - Intrusion Tone Repeat Time
After a user barges in, the system repeats the Barge-In tone after this interval.