Electra Elite IPK II Document Revision 1
Flexible Timeouts 2 - 411
Flexible Timeouts
Description
The Flexible Timeouts feature provides a variety of timers in the Resident System Program to allow the
system to operate without initial programming. The system timers can be changed to meet customer
needs according to the system application requirements.
A Timer Class is used to allow terminals and trunks to have different timers for the same feature. There
are 16 timer Classes (0~15). The following table shows the Programs that are used depending on the
Timer Class used:
Timer
Class 0
Timer
Class 1~15
Title Comment
20-01-08 20-31-01 Trunk Queuing Callback
Duration Time
Trunk Queuing callback rings an extension for this
interval. Station Timer Class is referred by the
station that sets trunk queuing.
20-01-09 20-31-02 Callback / Trunk Queuing
Cancel Time
The system cancels an extension’s Callback or
Trunk Queuing request after this interval. Station
Timer Class is referred by the station that sets an
extension’s Callback or Trunk Queuing.
20-04-03 20-31-03 Call Coverage Delay
Interval Time (Virtual
Extension Key)
If CAR/VE is set for Delayed Ringing (Program 15-
11-01), ring the covering extension after this
interval. Station Timer Class is referred by the
station assigned to CAR/VE.
21-01-02 20-31-04 Intercom Inter-digits Time When placing Intercom calls, users must dial each
digit within this interval. Station Timer Class is
referred by stations. Trunk Timer Class is referred
by DID/Automatic Answer Trunk/E&M trunks.
21-01-03 20-31-05 Trunk Inter-digits Time When placing CO calls, users must dial each digit
within this interval. Station Timer Class is referred
by stations. Trunk Timer Class is referred by DID/
Automatic Answer Trunk/E&M trunks.
21-01-09 20-31-06 Hotline Time Start Time A Ringdown extension automatically calls its
programmed destination after this interval. Station
Timer Class is referred by the stations which sets
Hotline.
22-01-03 20-31-07 Ring No Answer Alarm
Time
If a trunk rings a key telephone longer than this
interval, the system changes the ring cadence.
This indicates to the user that the call has been
ringing too long. Trunk Timer Class is referred by