Document Revision 1 Electra Elite IPK II
2 - 340 Door Box
Each channel in the PGD(2)-U10 ADP has a jumper which must be set for Door Box
operation. Refer to the Electra Elite IPK II System Hardware Manual for additional details.
The PGD(2)-U10 ADP can only be connected to an ESIB(8)-U20 ETU. if the PGD(2)-U10
ADP is connected to an ESIE(8)-U20 ETU, the PGD(2)-U10 ADP will NOT be recognized.
When a ESIB(8)-U20 ETU has an ESIE(8)-U20 ETU installed [ESIB/E(16)], the PGD(2)-
U10 ADP will have both channels available for Paging, MOH, External Ringers and Door
Box according to strapping on ports 1-8. The corresponding port on the ESIE(8)-U20 ETU
will not support a station or other hardware (it is used by the PGD(2)-U10 ADP for channel
2).
When a ESIB(8)-U20 ETU is installed without an ESIE(8)-U20 ETU installed, a PGD(2)-
U10 ADP installed on ports 1~8 will be recognized, but only channel 1 on the PGD(2)-U10
ADP is supported. Channel 2 is not available.
ESIB(8)-U10 ETUs and ESIE(8)-U10 ETUs do not support the PGD(2)-U10 ADP.
Default Setting
Disabled
System Availability
Terminals
All Stations
Required Component(s)
PGD(2)-U10 ADP
Programming
10-03-01 System Configuration - (ESI) ETU Setup – Channel 1 Terminal Type
10-03-06 System Configuration - (ESI) ETU Setup – Channel 2 Terminal Type
Set the terminal type to “8” for Door Box usage. First set 10-03-01 to 0 with no device plugged
into that port, then plug the device in and the system should recognize it as a door box and then
set 10-03-06.
10-05-01 General Purpose Relay Setup
Define which Relay circuits (5~8) on a PGD(2)-U10 ADP Adapter are used for General
Purpose Relay. Refer to Program 10-21-01 for the CPUII.