Document Revision 1 Electra Elite IPK II
2 - 368 D
term
IP Gateway System
SOFTWARE SUPPORT
TCP/IP protocol supports IP traffic and management.
RVPoIP uses UDP/IP protocol for voice transmission.
Serial RVP uses HDLC encapsulation for voice transmission.
Management and utilities include Telnet, inband RVP, RS-232 console interface (Gateway and
Branch), SNMP, and HTML.
Software upgradable, using FTP, between the Gateway and the branch, RS-232 serial port to PC,
or inband connection.
Conditions
Refer to D
term
IP Gateway System Administrator’s Guide or D
term
IP Gateway II System
Administrators Guide for more information.
TAPI is not supported.
When you dial 911 on your D
term
telephone, the 911 facility reached is the one that serves
the Gateway facility. To reach the correct 911 service for your area, use a telephone
connected locally. The D
term
IP Branch unit provides an analog port for local dialing.
Synchronous ringing does not work on the remote telephone. Incoming trunk calls
automatically ring 2 seconds on/2 seconds off.
Analog Fax machines and modems cannot operate with a D
term
Multiline Terminal that is
connected to an APR-U Unit or AP(A)-R Unit optional adapter.
The CT(A)-R Unit, CTA-U Unit, or CTU(S)-U Unit cannot be installed to a KTS remote
Multiline Terminal to provide TAPI functionality with the KTS.
The DTP-32DE-1 Multiline Terminal is the only one certified for use in a home environment.
None of the other D
term
Series E or Electra Elite Multiline Terminals are certified for home
use because of FCC restrictions, but they are approved for use in an office environment.
The HFU-U/HF-R Unit handsfree adapter cannot operate with a KTS remote Multiline
Terminal for home use because of FCC restrictions, but it is approved for use in an office
environment.
An applicable network terminating device must be installed and functioning at both the
corporate facility and the branch office.
The data connection between the corporate facility and the branch office must be
configured properly and operational.
Network termination equipment must support an RS-232, V.35 or RS-530 synchronous
interface or support IP devices over Ethernet.
The system operates from 100-240 VAC, 50-60 Hz. Power must not be applied to the
Gateway unit until specified in the installation procedures.