Document Revision 1 Electra Elite IPK II
2 - 370 D
term
IP Gateway System
Application Guide
PC for configuration
T1, Fractional T1, ISDN, Frame Relay or ATM circuit that can connect the Branch unit to
the Gateway location
A networking terminating device that can interface with the Gateway and Branch/Adapter units
and support synchronous serial protocol using RS-232, V.35, or RS-530 interface, or 10BaseT
Ethernet for an IP connection.
Network Requirements
The Gateway must be installed on an existing LAN or WAN network.
Each unit requires a network device that supports a synchronous serial interface or an
Ethernet connection to a TCP/IP network.
The network must be operational and active to complete installation of the Gateway.
The network device must support one of the following:
J
Synchronous serial signaling on its data port using an RS-232, V.35, or RS-530 interface
J
10BaseT Ethernet connections
Related Features
None
Programming
None
Operation
Operates the same as any Electra Elite Multiline Terminal