Document Revision 1 Electra Elite IPK II
2 - 404 Flash
Related Features
Drop Key
PBX Compatibility
Toll Restriction
Voice Mail
Programming
11-12-42 Flash on Trunk Lines
Assign Service Code, default = #3.
14-02-03 Analog Trunk Data Setup - Flashing/Grounding
Make sure this item is set for open loop Flash (0).
14-02-04 Analog Trunk Data Setup - Flash for Timed Flash or Disconnect
For each trunk, indicate if Flash is for Flash (0) or open loop disconnect (1).
15-02-05 Multiline Telephone Basic Data Setup - Transfer Key Operation Mode
In order for the Cordless Lite/Cordless Lite II telephone user to be able to use the flash function,
this option must be set to “2”. This changes the Transfer key to a Flash key.
15-03-04 Single Line Telephone Basic Data Setup - Flashing
In a single line (500/2500 type) telephone’s Class of Service, enable (1) or disable (0) the ability
to hookflash for system feature access.
81-01-14 COI Initial Data Setup - Hookflash 1
Set the Flash duration (16 ~ 4080 ms) for analog trunk [COI( )-U( ) ETU] circuits in PRG
81-10-07.
81-01-15 COI Initial Data Setup - Hookflash 2
Set the open loop disconnect duration (16~4080 ms) for analog trunk [COI( )-U( ) ETU] circuits
PRG 81-10-08.