Document Revision 1 Electra Elite IPK II
2 - 414 Flexible Timeouts
Required Component(s)
None
Related Features
None
Programming
20-29-01 Timer Class for Extensions
Assign the timer class (0~16) to each extension for each Night mode. This entry includes
virtual extension number.
20-30-01 Timer Class for Trunks
Assign the timer class (0~16) to each trunk for each Night mode.
20-31-01~23 Timer Class – Timer Assignment
Assign times. These timers are referred when a class is set any number from 1 to 16 in 20-
29-01/20-30-01. When the timer class is set to 0 in 20-29-01/20-30-01, current timer
(system-wide basis) is referred refer to the table above for more detailed information about
the programs.
Operation
Please refer to the feature for the operation.