Electra Elite IPK II Document Revision 1
IP Station (MEGACO) - MG 16 2 - 477
84-11-22 TX Gain
Use this program to define to TX Gain Values –Adjusting this value will increase or decrease
volume levels for the receiving party. Consult the Electra Elite IPK II Programming Manual for
Transmit Gail scale to set acceptable value.
(default: 10)
84-11-22 RX Gain
Use this program to define to RX Gain Values –Adjusting this value will increase or decrease
volume levels for the sending party. Consult the Electra Elite IPK II Programming Manual for
Transmit Gail scale to set acceptable value.
(default: 10)
Operation
Example Configuration 1 - Static IP Addressing, One LAN:
This example shows System IP Phones connected to a single LAN (no routers) with a static IP address.
Programming - IPK II CPU
1. 10-12-01 IPK II CPU Network Setup - IP Address = 192.168.1.20
2. 10-12-02 IPK II CPU Network Setup - Subnet Mask = 255.255.255.0
Figure 2-3 Example - Static IP Addressing, One LAN
IPK II CPU: 192.168.1.20
VoIP MG16: 192.168.1.21
Subnet Mask: 255.255.255.0
Default Gateway: 192.168.1.254
IPK II CPU
VoIP MG16
Switch/Hub
IP Phone 1/ EXT 100
192.168.1.200
IP Phone 1/ EXT 101
192.168.1.201