Document Revision 1 Electra Elite IPK II
2 - 522 ISDN Compatibility
Related Features
Central Office Calls, Answering
Central Office Calls, Placing
Direct Inward Dialing (DID)
Direct Inward Line (DIL)
E-911 Compatibility
Forced Trunk Disconnect
Station Message Detail Recording
Transfer
Programming
ISDN - BRI Installation
10-03-01 ETU Setup - ISDN Line Mode
Setup and confirm the Basic Configuration data for each BRT (4)-U20 ETU. Use this program to
select the ISDN Line Mode.
0 = Not Set
1 = T-Bus (Default)
10-03-03 ETU Setup – Connection Type
Setup and confirm the Basic Configuration data for each BRT (4)-U20 ETU. Confirm the
connection type for or each BRT (4)-U20 ETU.
0 = Point-to-Multipoint (Default)
1 = Point-to-Point
10-03-04 ETU Setup - Layer 3 Timer Type
Setup and confirm the Basic Configuration data for each BRT (4)-U20 ETU. This program
selects the Layer 3 timer type (1~5). Each timer value of Layer 3 is set up for each type in
Program 81-06 (T-Bus).