Document Revision 1 Electra Elite IPK II
2 - 562 Long Conversation Cutoff
Related Features
Central Office Calls, Answering
Central Office Calls, Placing
Direct Inward System Access (DISA)
Tie Lines
Warning Tone for Long Conversation
Programming
14-01-14 Basic Trunk Data Setup - Long Conversation Cutoff
Enable (1) or disable (0) a trunk’s ability to disconnect incoming and outgoing central office calls
automatically.
14-01-15 Basic Trunk Data Setup - Long Conversation Alarm Before Cut Off
Enable (1) or disable (0) the Long Conversation Alarm for each trunk.
20-06-01 Class of Service for Extensions
Assign a Class of Service (1~15) to extensions.
20-13-02 Class of Service Options (Supplementary Service) - Long Conversation Cutoff (Incoming)
Enable (1) or disable (0) an extension’s class of service from using Long Conversation Cutoff for
incoming calls.
20-13-03 Class of Service Options (Supplementary Service) - Long Conversation Cutoff
(Outgoing)
Enable (1) or disable (0) an extension’s class of service from using Long Conversation Cutoff for
outgoing calls.
20-21-03 System Options for Long Conversation - Long Conversation Cutoff for Incoming Calls
Enter the time the system will wait before disconnecting incoming trunks (0~64800 seconds).
20-21-04 System Options for Long Conversation - Long Conversation Cutoff for Outgoing Calls
Enter the time the system will wait before disconnecting outgoing trunks (0~64800 seconds).