T1 Trunking (with ANI/DNIS Compatibility) 2 - 807
20-06-01 Class of Service for Extensions
Assign a Class of Service (1~15) to an extension.
20-09-02 Class of Service Options (Incoming Call Service) - Caller ID Display
Turn off (0) or on (1) the Caller ID display at an extension.
20-09-01 Class of Service Options (Incoming Call Service) - Second Call for DID/DISA/DIL/E&M
Enable (1) or disable (0) an extension’s ability to receive a second call from a DID, DISA, DIL, or
tie line caller. With this option set to ‘1’, the destination extension must be busy in order for a
second DNIS caller to ring through. If the destination extension does not have a line or Call
Appearance (CAP) Key available for the second call and a previous call is ringing the extension
but has not yet been answered, the second caller will hear busy regardless of this program’s
setting.
20-14-01 Class of Service Options for DISA/E&M
Enable/disable tie line Class of Service options. Assign tie line Classes of Service in 34-02. Up
to 15 DISA/E&M Classes of Service can be defined.
22-02-01 Incoming Call Trunk Setup
For each T1 trunk, set the Trunk Service Type to match the Telco’s connected T1 service. For
each T1 trunk that should support ANI/DNIS service, enter 7. (ANI/DNIS trunks must be
immediate start or wink start T1 trunks with E&M signaling.) For T1 loop/ground start trunks
defined as “0”, Program 14-02-02 must be set to ‘1’ in order for the trunks to ring and lamp
correctly.
22-13-01 DID Trunk Group to Translation Table Assignment
Assign DID translation tables to trunk groups.
DID Translation Tables: 1~20
Trunk Groups: 1~100
34-01-01 E&M Tie Line Basic Setup - DID/E&M Start Signaling
For each ANI/DNIS trunk, set the start signaling mode to 1 (wink start).
34-01-02 E&M Tie Line Basic Setup - Receive Dial Type for E&M Tie Line
For ANI/DNIS, the following additional setting in Program 34-01-02 is recommended:
(Receive Dial Type for E&M Tie Line = 1 (DTMF)
34-01-03 E&M Tie Line Basic Setup - E&M Dial-In Mode
Determine if the incoming tie line call should be directed as an intercom call (0) or if it should
follow the DID Translation Table in Program 22-11 (1).
34-10-04 E&M Tie Line Basic Setup - E&M Line Dial Tone
Determine whether the tie line should send dial tone to the calling system once the call is set up
(1) or not (0).
34-02-01 E&M Tie Line Class of Service
Assign a Class of Service (1-15) to a tie line. The Class of Service options are defined in
Program 20-14. For each tie line, you make a separate entry for each Night Service mode.