Document Revision 1 Electra Elite IPK II
2 - 884 Uniform Numbering Network
44-05-03 ARS/F-Route Table - Additional Dial Number Table
Enter the table number (defined in Program 44-06) for additional digits to be dialed (0~1000).
44-05-04 ARS/F-Route Table - Beep Tone
For each ARS/F-Route table (1~500) assign a priority number (1~4). Select whether or not a
beep is heard if a lower priority trunk group is used (0 = No Beep, 1 = Beep).
44-05-05 ARS/F-Route Table - Gain Table Number for Internal Call
For each ARS/F-Route table (1~500) assign a priority number (1~4). Select the gain table
number to be used for internal calls (0~500).
44-05-06 ARS/F-Route Table - Gain Table Number for Tandem Connections
For each ARS/F-Route table (1~500) assign a priority number (1~4). Select the gain table
number to be used for tandem connection (0~500).
44-05-07 ARS/F-Route Table - ARS Class of Service
For each ARS/F-Route table (1~500) assign a priority number (1~4). Select the Class of Service
to be used for ARS (0~16). An extensions ARS COS is determined in Program 26-04-01.
44-05-08 ARS/F-Route Table - Dial Treatment
For each ARS/F-Route table (1~500) assign a priority number (1~4). Select the Dial Treatment
to be used (0~15). The Dial Treatments are determined in Program 26-03-01.
14-02-09 Busy Tone Detection
0 = Disable (default)
1 = Enable
14-02-14 Analog Trunk Data Setup - Loop Start/Ground Start
0 = Loop Start (default)
1 = Ground Start