Document Revision 1 Electra Elite IPK II
2 - 70 Automatic Route Selection
26-02-03 Dial Analysis Table for ARS - Additional Data / Service Number
For each Dial Analysis Table (1~200), if Service Type 1 was selected in Program 26-02-02,
enter the trunk group number (0~100, 0 = No Route).
26-02-04 Dial Analysis Table for ARS - ARS Class of Service
For each Dial Analysis Table (1~200), set the Automatic Route Selection (ARS) Class of Service
(0-16).
26-02-05 Dial Analysis Table for ARS - Dial Treatment
For each Dial Analysis Table (1~200), set the Automatic Route Selection (ARS) Dial Treatment
(0~15) to be used.
26-03-01 ARS Dial Treatments
Assign the Dial Treatments (1~15) for automatic ARS dialing translation. Assign Dial Treatments
to Service Numbers (Trunk Groups) in Program 26-02. The ARS Dial Treatment options are:
H
3 - Delete the NPA if dialed as part of the initial call. This requires at least eight digits in the ARS
table (Program 26-02-01).
H
2 - Delete the leading digit if dialed as part of the initial call. This requires at least eight digits in
the ARS table (Program 26-02-01).
H
1 - Add a leading 1 if not dialed as part of the initial call. This requires at least eight digits in the
ARS table (Program 26-02-01).
H
INPA - Insert the NPA specified by NPA.
H
DNN - Outdial the NN number of digits or execute the code that follows. For example, D041234
out-dials 124. Valid entries are 0~9, #,
,
, Wnn (wait nn seconds) and P (pause). Each digits code
counts as a digit. So for example, if a P was added for a pause, the entry would look like:
D05P1234. This Dial Treatment can only be added from telephone programming.
H
Wnn - Wait nn seconds.
H
P - Pause in analog trunk.
H
R - Redial the initially dialed number, including any modifications.
H
E - End of Dial Treatment. All Dial Treatments must end with the E code.
H
X - When ARS is enabled, X must be entered in the Dial Treatment in order for the system to
output the extension number of the call’s originator to the black box for the E911 feature.
26-04-01 ARS Class of Service
Set an extension’s ARS Class of Service (0~16). Automatic Route Selection uses ARS Class of
Service when determining how to route an extension’s calls.
26-11-01 Transit Network ID Table
Enter the Transit Network Selection information element to be added to an ARS call using an
ISDN trunk. This information element identifies a requested transit network.

Table of Contents