1. Before Setting Up Your Projector
• C2 connection
AC power is provided to the projector power supply and the light power supply by separate cables.
AC power supply cable
AC power supply
cable
Electric outlet
Input Selection
C2 connection
Projector
(Main unit)
Light power
supply unit
AC power supply
equipment
AC power supply
equipment
Breaker
Breaker
AC power supply equipment
Do not connect AC power supply voltages to the projector other than those indicated below.
When using with a C1 connection
• 200-240VAC,singlephase,50/60Hz
When using with a C2 connection
• 200-240VAC,singlephase,50/60Hz(projectorpowersupply)
• 200-240VAC,singlephase,50/60Hz(lightpowersupply)
Breakers
When connecting the AC power supply from the power supply equipment of the building to the projector, be sure to
connect it through a breaker. The capacity of the breaker must be as indicated below.
When using with a C1 connection
• Powersupplyforprojector+powersupplyforlight
200V-240 V AC: Input current 40A, Inrush current 150A or higher @10msec
When using with a C2 connection
• Powersupplyforprojector
200V-240 V AC: Input current 10A, Inrush current 60A or higher @10msec
• Powersupplyforlight
200V-240 V AC: Input current 40A, Inrush current 150A or higher @10msec