27
1. Before Setting Up Your Projector
WARNING
• Thepowersupplyunithandleslargeelectricalcurrents.Tomaintainsafety,usewireswiththespecicationsas
shown in the following table, and affix to the terminals at the designated attachment torque.
• Alwaysusesolderlessterminalswiththedimensionsasshowninthefollowingdiagram.
• TheuseofpartswithdimensionsotherthanasdesignatedcreatesariskoftheACpowersupplyunitshort
circuiting due to the terminal block generating heat and melting because the terminal block of the light power
supply unit cannot be attached correctly.
• Power supply terminal L, N (Black)
AC power is provided to the projector power supply and the light power supply by a single cable.
JIS IEC/EN UL CSA
Thickness of compatible
wiring (using solderless ter-
minal)
14 mm
2
14 mm
2
AWG6 or
AWG8
AWG6 or
AWG8
Solderless terminal dimen-
sions
M5 x 10
Tightening torque 2.0 to 2.5N·m
Solderless terminal dimen-
sions
Min 1.0
Min 1.0
-Max 2.0
-Max 2.0
Max 5.8
Min ⌀6.1
Max 12.2
Min 4.5
Unit: mm
Solderless terminal recom-
mended part (J.S.T parts)
Model R8-5 When using AWG6: Model R14-5
When using AWG8: Model R8-5
J.S.T: J.S.T. Manufacturing Co. Ltd.