UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 1035
51-07-02 Net-Link Primary Compulsion
Specification Setting – Package
Reset Timing Option
When Forced Change Primary
System is done, all packages will
reset. This option can select the
timing of package reset.
0 = Reset when all packages are in
idle condition, otherwise reject
Primary System Integration.
1 = Anytime
0 = Off
1 = On
(default = 0)
3
51-08-01 Primary Net-Link Setting – IP
Address of New Primary System
Enter target IP address for New
Primary system. When the Forced
Change Primary system is done, this
setting will be erased.
0.0.0.0 ~
126.255.255.254
128.0.0.1 ~
191.255.255.254
192.0.0.1 ~
223.255.255.254
(default = 0.0.0.0)
3
51-08-02 Primary Net-Link Setting –
System ID of New Primary System
When set to 0, top priority Primary
system is assumed to be the new
Primary system.
0~50
(default not assigned)
3
51-09-01 Net-Link Communication Port
Settings – Primary Waiting Port
Sets the communication port that the
Primary system uses to
communicate with the Secondary
system.
0~65535
(default = 58000)
3
51-09-02 Net-Link Communication Port
Settings – Communication
Waiting Port
Port used to communicate between
nodes. It is always opened by all
nodes.
0~65535
(default = 58001)
3
51-09-03 Net-Link Communication Port
Settings – Secondary
Communication Port
Secondary system communicates
with Primary system at this port
number. If 0 is specified, temporary
port is selected by dynamic.
0~65535
(default = 0)
3
51-09-04 Net-Link Communication Port
Settings – Primary Search Port
When Fail-Over occurred, each
system communicates with other
system at this port number.
If 0 is set, temporary port is selected
by dynamic.
If 0 is not specified, the number and
continuous maximum 50 number is
used.
(Ex. 5000 is specified 5001,
5002…5049 will be used).
0~65535
(default = 0)
3
51-09-05 Net-Link Communication Port
Settings – Primary Detection Port
Enter port number to seek the Top
Priority Primary system.
If 0 is specified, temporary port is
selected by dynamic.
0~65535
(default = 0)
3
51-09-06 Net-Link Communication Port
Settings – Database Replication
Communication Listening Port
This port is used to replicate
database.
0~65535
(default =
58002)
3
51-09-07 Net-Link Communication Port
Settings – Database Replication
Primary Detection Port
This port is used to replicate
database.
If 0 is specified, temporary port is
selected by dynamic.
0~65535
(default = 0)
3
51-10-01 Virtual Slot Setting – Number of
Available Virtual Slots
240 slots can be controlled in
NetLink. This command can check
how many slots are available.
(default not assigned)
3
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3