Issue 1.0 UNIVERGE SV8100
2 - 1076 T1 Trunking (with ANI/DNIS Compatibility)
34-09-04 ANI/DNIS Service Options –
Route Table Setup of Target Dial
The option sets how the system
uses the route data (gathered in
Item 3) to route incoming ANI/DNIS
calls (0 = ABB Table [Program 13-
04], 1 = DID Table [Program 22-
11]).
If option 2 is selected and the call
is to be routed using the DID table
(1), up to eight digits can be
matched. The number of expected
digits set in Program 22-09-01
must match the ANI digits defined
in Program 22-11-01. For example,
if an ANI/DNIS number received
was 20355512343001 and
Program 22-09-01=4, then the
entry in Program 22-11-01 must be
1234 with the defined target
extension.
If the call is to be routed using the
ABB table (0), up to 24 digits can
be matched. Define the range of
the ABB table to be used in
Program 34-09-06. The data is
then compared to the entries in
Program 13-04-01 and then routed
according to Program 13-04-03.
0 = SPD Table (Program
13-03)
1 = DID Table (Program
22-11)
(default = 0 for
COS 1~15)
3
34-09-05 ANI/DNIS Service Options – ANI/
DNIS Display as Target Dial Name
Use this option to set if ANI data
should appear on telephone
displays as part of Caller ID
display.
Caller ID Display:
0 = Display Off
1 = Display On
(default = 1 for
COS 1~14
default = 0 for COS 15)
3
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3