UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 1181
16-01-04 Department Group Basic Data
Setup – Hunting Mode
Set if an unanswered call should
hunt once stopping at the last
member tried (0) or continually hunt
through the idle members (1).
0 = Last extension is
called and hunting is
stopped
1 = Circular
(default = 0)
3
16-01-05 Department Group Basic Data
Setup – Extension Group All Ring
Mode Operation
Set if all members of the group
should ring automatically (1) or
through the use of the service code
(0) defined in Program 11-12-09.
Selecting automatic will override
the settings of Programs 16-01-03
and 16-01-04.
0 = Manual
1 = Automatic
(default = 0)
3
16-01-06 Department Group Basic Data
Setup – STG Withdraw Mode
Use to set the STG withdraw mode
for each department group.
0 = Disable (Camp On)
1 = Enable (Overflow
Mode)
(default = 0)
3
16-01-07 Department Group Basic Data
Setup – Call Recall Restriction for
STG
Determine whether or not an
unanswered call transferred to a
Department Group should recall the
extension from which it was
transferred.
0 = Disable (Recall)
1 = Enable (No Recall)
(default = 0)
3
16-01-09 Department Group Basic Data
Setup – Department Hunting No
Answer Time
Set how long a call rings a
Department Group extension
before hunting occurs.
64800 (seconds)
(default = 15 seconds)
3
16-01-10 Department Group Basic Data
Setup – Enhanced Hunt Type
Set the type of hunting for each
Department Group:
0 = No Queuing
1 = Hunting When Busy
2 = Hunting When Not Answered
3 = Hunting When Busy or No
Answer
0 = No queuing
1 = Hunting When Busy
2 = Hunting When Not
Answered
3 = Hunting When Busy
or No Answer
(default = 0)
3
16-02-01 Department Group Assignment
for Extensions
Set up the Department Group
called by the pilot number and the
extension priority when a group is
called.
Call Pickup Groups are set up in
23-02.
Department Groups
1-64
Priority 1-512
Default = All extensions
in Department Group 1
with priority in port
order:
Port 1 priority = 1
Port 512 priority = 512
3
16-03-01 Secondary Department Group Use this program to assign
extensions to multiple Department
Groups and set the priority
assignment. Each Secondary
Department Group can have up to
16 extensions assigned.
Extension Number
Maximum eight digits
Priority Order
0~999
(default not assigned)
3
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3