Issue 1.0 UNIVERGE SV8100
2 - 1312 Wireless DECT (SIP)
84-19-05 SIP Extension CODEC
Information Basic Setup – G.711
Jitter Buffer (average)
Use this program to define G.711
Jitter Buffer average accepted value
– values are set in ms.
0~160 ms
(default = 40 ms)
3
84-19-06 SIP Extension CODEC
Information Basic Setup – G.711
Jitter Buffer (max)
Use this program to define G.711
Jitter Buffer maximum accepted value
– values are set in ms.
0~160 ms
(default = 80 ms)
3
84-19-07 SIP Extension CODEC
Information Basic Setup –
Number of G.729 Audio Frames
Use this program to define the G.729
audio Frame Size.
1~6
1 = 10 ms
2 = 20 ms
3 = 30 ms
4 = 40 ms
5 = 50 ms
6 = 60 ms
(default = 2)
3
84-19-08 SIP Extension CODEC
Information Basic Setup – G.729
Voice Activity Detection Mode
Use this program to Enable or
Disable Voice Activity Detection for
G.729.
0 = Disabled
1 = Enabled
(default = 0)
3
84-19-09 SIP Extension CODEC
Information Basic Setup – G.729
Jitter Buffer (min)
Use this program to define G.729
Jitter Buffer minimum accepted value
– values are set in ms.
0~270 ms
(default = 20 ms)
3
84-19-10 SIP Extension CODEC
Information Basic Setup – G729
Jitter Buffer (average)
Use this program to define G.729
Jitter Buffer average accepted value
– values are set in ms.
0~270 ms
(default = 40 ms)
3
84-19-11 SIP Extension CODEC
Information Basic Setup – G729
Jitter Buffer (max)
Use this program to define G.729
Jitter Buffer maximum accepted value
– values are set in ms.
0~270 ms
(default =80 ms)
3
84-19-17 SIP Extension CODEC
Information Basic Setup – Jitter
Buffer Mode
Use this program to define the Jitter
Buffer mode – supported Static or
Immediate.
1 = Static
2 = Adaptive during
Silence
3 = Adaptive
Immediately
(default = 3)
3
84-19-18 SIP Extension CODEC
Information Basic Setup – VAD
Threshold
Use this program to define the VAD
Threshold – Values set in db. Consult
the UNIVERGE SV8100
Programming Manual for Threshold
scale to set acceptable values.
0~30
(default = 20)
3
84-19-26 SIP Extension CODEC
Information Basic Setup – TX
Gain
Use this program to define to TX Gain
Values – Adjusting this value
increases or decreases volume levels
for the receiving party. Consult the
UNIVERGE SV8100 Programming
Manual for Transmit Gain scale to set
acceptable value.
0~40 =
(-20dbm ~ +20dbm)
0 =-20 dbm
1 =-19 dbm
:
20 =0 dbm
:
39 =+19 dbm
40 =+20 dbm
(default =20)
3
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3

Table of Contents

Other manuals for NEC Univerge SV8100