UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 235
20-07-12 Class of Service Options
(Administrator Level) – Trunk
Port Disable
Turns Off (0) or On (1) the
extension ability to use the Trunk
Port Disable feature.
0 = Off
1 = On
(default = 0 for
COS 1~14)
(default = 1 for
COS 15)
3
20-08-02 Class of Service Options
(Outgoing Call Service) – Trunk
Outgoing Calls
Turns Off (0) or On (1) outgoing
trunk calling for the extension.
0 = Off
1 = On
(default = 1 for
COS 1~15)
3
20-13-13 Class of Service Options
(Supplementary Service) –
Continued Dialing (DTMF) Signal
on ICM Call
Turns Off (0) or On (1) the
extension ability to use Continued
Dialing, which allows DTMF signal
sending while talking on extension.
0 = Off
1 = On
(default = 1 for
COS 1~15)
3
21-01-15 System Options for Outgoing
Calls – Outgoing Disable on
Incoming Line (Toll Restriction)
Enable or Disable the Outgoing
Disable on Incoming Line feature.
0 = Disable
1 = Enable
(default = 1)
3
21-01-16 System Options for Outgoing
Calls – Supervise Dial Detection
Timer
With the Outgoing Disable on
Incoming Line feature, if dial tone is
not detected after the extension
answers an incoming line, the
system determines the call is
unable to complete and releases
the DTMF receiver.
0~64800 (seconds)
(default = 20 seconds)
3
21-01-17 System Options for Outgoing
Calls – Restriction Digit in
Outgoing Disable on Incoming
Line
With the Outgoing Disable on
Incoming Line feature, determine
the number of digits (0~9) to be
dialed before the call should be
disconnected.
Digits 0~9
(default = 4)
3
21-02-01 Trunk Group Routing for
Extensions
Assign Program 14-06 routes to
extensions.
0~100
(0 = No Setting)
(default = 1)
3
21-15-01 Individual Trunk Group Routing
for Extensions
Designate the trunk route accessed
when a user dials the Alternate
Trunk Route Access Code. Refer to
Trunk Group Routing to set up
outbound routing.
0~100
(0 = No Setting)
(default = 0)
3
24-02-07 System Options for Transfer –
Trunk-to-Trunk Transfer Release
Warning Tone
Timer starts when a trunk begins
talking with another trunk (for
example: Trunk-to-Trunk Transfer,
outgoing from trunk, Tandem
Trunking). When this time expires, a
warning tone is heard.
0~64800 (seconds)
(default = 1800
seconds)
3
24-02-10 System Options for Transfer –
Disconnect Trunk to Trunk Timer
Timer starts after the Warning Tone
is heard (24-02-07). When time
expires, the trunk is disconnected.
0~64800 (seconds)
(default = 0 seconds)
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3