Issue 1.0 UNIVERGE SV8100
2 - 662 ISDN Compatibility
ISDN – PRI Installation
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3
10-03-04 ETU Setup (PRTA PKG Setup) –
Layer 3 Timer Type
Setup and confirm the Basic
Configuration data for each
CD-PRTA This program selects
the Layer 3 timer type (1~5). Each
timer value of Layer 3 is set up for
each type in Program 81-06
(T-Bus).
1~5
(default = 1)
3
10-03-06 ETU Setup (PRTA PKG Setup) –
Length of Cable
Setup and confirm the Basic
Configuration data for each
CD-PRTA. Select the length of
cable to be used.
0 = Level 1
1 = Level 2
2 = Level 3
3 = Level 4
4 = Level 5
(default = 2)
3
10-03-08 ETU Setup (PRTA PKG Setup) –
Dial Sending Mode
ISDN protocol definition. Select
either enblock or overlap sending.
0 = Enblock Sending
1 = Overlap Sending
(default = 0)
3
10-03-09 ETU Setup (PRTA PKG Setup) –
Dial Information Element
ISDN protocol definition. If Overlap
Sending is selected in Program
10-03-08, select either Keypad
Facility (0) or Called Party Number
(1) for the dial information
element.
0 = Keypad Facility
1 = Called Party Number
(default = 0)
3
10-03-18 ETU Setup (PRTA PKG Setup) –
Type of Number
Select the number type for the
ISDN circuit.
0 = Unknown
1 = International number
2 = National number
3 = Network Specific
number
4 = Subscriber number
5 = Abbreviated number
(default = 2)
3
10-03-19 ETU Setup (PRTA PKG Setup) –
Numbering Plan Identification
Select the Numbering Plan used
for the ISDN circuit.
0 = Unknown
1 = ISDN numbering
plan
2 = Data numbering plan
3 = Telex numbering
plan
4 = National standard
numbering plan
5 = Private numbering
plan
(default = 1)
3