Chapter 5 System Data Mode
5-7 NWA-033628-001 Rev.1.0
Using System Data Mode
Special System Data Entered in the System Data Mode
This section describes the description of special system data (CM05, 10, 20, 90, 97, 9A) entered in the Sys-
tem Data Mode.
CM05
Y 1ST DATA 2ND DATA
No. MEANING
DATA MEANING DATA MEANING
0 Blade Type XX ZZ XX : Unit No. (01-50)
ZZ : Slot No. (01-18)
10 Digital Line Circuit Blade for
Multiline Terminal/DSS
Console (CD-8DLCA/
CD-16DLCA)
20 Analog Line Circuit Blade for
Single Line Telephone
(CD-4LCA/CD-8LCA)
21 LLC (OPX) Blade
(CD-4DIOPA/CD-4DIOPB)
30 C.O. Trunk Blade (CD-4COTB)
31 OD Trunk Blade
(CD-4DIOPA/CD-4DIOPB)
32 Direct Inward Dialing Trunk
Blade (CD-4DIOPA/
CD-4DIOPB)
33 LD Trunk Blade
(CD-4DIOPA/CD-4DIOPB)
40 Basic Rate (2B + D) Interface
Trunk Blade (CD-2BRIA)
41 ISDN Primary Rate (23B + D/
30B + D) Interface Blade
(CD-PRTA)
42 CCIS (1.5 Mbps/2 Mbps)
Trunk Blade (CD-CCTA)
43 T1 (1.5 Mbps)/E1 (2 Mbps)
Digital Trunk Interface Blade
(CD-PRTA)
45 QSIG (CD-PRTA)
50 CS/ZT Interface Blade
(CD-4CSIB)
Continued on next page