Control
67
FIGHTER 1330
6.0 External units*
Menu 6.8.10 Periodtime shunt
The period time for the shunt (SV-K) is chosen
here. Adjustable between 1 and 500 seconds. The
factory setting is 60 seconds.
Menu 6.8.11 Shunt intensificat.
The amplification for the shunt (SV-K) is chosen
here. For example, a 2 degrees difference between
the flow and the calculated flow line with 5 in ampli-
fication gives 10 sec/min controling the shunt. The
value can be set between 1 and 10. The factory
setting is 1.
Menu 6.8.12 Return
Pressing the Enter button returns you to menu
6.8.0.
U
N
N
* Only shown when the accessory in question is
connected and activated in menu 9.3.x.
Menu 6.8.0 Cooling settings
Pressing the enter button takes you to sub-menus
with the cooling settings. Only shown when cooling
accumulator is selected in menu 9.1.10.
Menu 6.8.1 Cool acc temperature
Shows the current temperature on the cooling
accumulator sensor (KBack).
Menu 6.8.2 Brine collector
Shows the current temperature on the collector for
the brine (KB-KO).
Menu 6.8.3 Cooling curve
The selected curve slope (cooling curve) is shown
here). The value can be set between 1 and 3. The
factory setting is 2.
Menu 6.8.4 Offset cooling curve
The selected cooling curve offset is shown here.
The value can be set between -10 and +10. The
factory setting is 0.
Menu 6.8.5 Start temp. heating
Outdoor temperature (menu 4.0) at the outdoor
sensor (UG) when the heat pump is permitted to
produce heat. The value can be set between 0 and
30 °C. The factory setting is 20 °C.
Menu 6.8.6 Start temp. cooling
Outdoor temperature (menu 4.0) at the outdoor
sensor (UG) when the heat pump is permitted to
produce cooling. The value can be set between 0
and 30 °C. The factory setting is 25 °C.
Menu 6.8.7 Temp. to cool. acc.
The desired temperature for the cooling accumula-
tor is set here. The value can be set between 0 and
20 °C. The factory setting is 13 °C.
Menu 6.8.8 Cooldiff for acc.
The required cooling difference for the accumulator
is set here. The value is adjustable between 1 and
10 °C. The factory setting is 2 °C.
Menu 6.8.9 Min. flow temp.
The lowest flow temperature in cooling mode. The
value is adjustable between 2 and 65 °C. The fac-
tory setting is 5 °C.