Control
FIGHTER 1330
66
6.0 External units*
Menu 6.7.0 Collector
Pressing the enter button takes you to sub-menus
with settings for load collector. Only shown when
the collector is On in menu 9.1.9.
Menu 6.7.1 Load collector temp.
Shows the current temperature on the load collec-
tor sensor (LKG).
Menu 6.7.2 Soil sensor temp.
Shows the current temperature on the soil sensor
(MG).
Menu 6.7.3 Mindiff for collect.
The minimum difference between the load collector
sensor (LKG) and the soil sensor (MG) to charge
from the load collector to soil is set here. The value
is adjustable between 1 and 25 °C. The factory set-
ting is 2 °C.
Menu 6.7.4 Maxdiff for collect.
The maximum difference between the load col-
lector sensor (LKG) and the soil sensor (MG) to
charge from the load collector to soil is set here.
The value is adjustable between 1 and 25 °C. The
factory setting is 10 °C.
Menu 6.7.5 Contload bripu col/e
Here you select whether the brine pump should run
continuously when loading from the load collector
to soil.
Menu 6.7.6 Load collector only
The temperature on the load collector sensor (LKG)
is set here when only the load collect is used. The
value can be set between -0 and +40 °C or Off. The
factory setting is Off.
Menu 6.7.7 Return
Pressing the enter button returns you to menu
9.7.0
U
U
U
U
N
N
N
N
* Only shown when the accessory in question is con-
nected and activated in menu 9.1.x.
Menu 6.6.0 HW storage vessel
Shows the current temperature in the hot water
accumulator. Pressing the enter button takes you to
sub-menus for the hot water accumulator settings.
Only shown when hot water accumulator is select-
ed in menu 9.1.6.
Menu 6.6.1 Loading temperature
The temperature that the control valve (SV-VVX)
attempts to reach on the hot water charging sensor
(VVLG). The value is adjustable between 40 and
60 °C. The factory setting is 48 °C.
Menu 6.6.2 Per.-Time shuntvalve
The period time for the control valve (SV-VVX) is
set here. Adjustable between 10 and 500 seconds.
The factory setting is 60 seconds.
Menu 6.6.3 Shunt intensificat.
Applies to the control valve (SV-VVX). The value is
adjustable between 1 and 10. The factory setting
is 2.
Menu 6.6.4 Return
Pressing the enter button returns you to menu
6.6.0.
U
U
U
U
N
Normal menus: displayed in all menu modes.
Extended menus: Only displayed when extended
or service is selected in menu 8.1.1.
Service menus: Only displayed when service is
selected in menu 8.1.1.
U
S
N