English – 5
tionofthelowerleafmotorcomparedwiththeupperoneThisisnecessary
inordertopreventtheleafsfromgettingstuck.Thereisalwaysastandard
delay during closing, calculated automatically by the control unit in order to
ensure the same delay as the one programmed for opening.
5.2.3 - Level one programming: part two
• Stand By / Phototest function:Thecontrolunithasthe“Everythingin
standby”functionpreset.Ifthisfunctionisactive,1minuteaftertheendof
a manoeuvre the control unit turns off the “Everything in stand by” output
(terminalno.8)andalltheInputsandotherOutputstoreduceconsumptions
(see electrical diagram in g. 5a).Thisfunctionisobligatoryifthecontrol
unit is powered exclusively with Solemyo photovoltaic panels. It is also rec-
ommended if the control panel is powered from the electric mains and if
youwishtoextendemergencyoperationwiththebufferbatteryPS124.As
an alternative to the “Everything in stand by” function, the “Phototest” func-
tionmaybeactivated.Thisveriesatthebeginningofamanoeuvrethatthe
connectedphotocellsoperatecorrectly.Tousethisfunction,connectthe
photocells correctly (see electrical diagram in g. 5c)andthenactivatethe
function.
• Open gate indicator light / electric lock: If the function is activated, termi-
nals 6-7 can be used to connect up the electric lock. If the function is deacti-
vated,terminals6-7canbeusedtoconnectupa24Vgateopenindicator.
• NC Type or Constant Resistance STOP Input: If the function is activated,
theSTOPinputissetto“8.2KΩConstantResistance”.Inthiscase,there
mustbea8.2KΩ+/-25%resistancebetweenthecommonandtheinputto
enabletheoperation.Ifthefunctionisnotset,thecongurationoftheSTOP
input will enable it to function with NC type contacts.
• Light/heavy gates : If the function is activated, the control unit enables the
user to manage heavy gates, setting the acceleration ramps and slowdown
speeds during closing differently. If the function is deactivated, the control
unit will be set to manage light gates.
• Proportional gate open indicator: If the function is activated, the gate open
indicatoroutputwillbesetwiththeproportionalashinglight.Thismeans
thatduringopening,theashingbecomesmoreintenseastheleafscome
nearertotheopeningstops;vice-versa,forclosing,theashingbecomesless
intense as the leafs come nearer to the closing stops. If the function is deacti-
vated,thelightwillashslowlyduringopeningandrapidlyduringclosing.
5.2.4 - Level two functions
• Pause time: Thepausetime,namelythetimewhichlapsesbetweenopen-
ingandclosingduringautomaticfunctioning,canbeprogrammedto5,10,
20,40,and80seconds.
• Auxiliary input AUX: Thecontrolunitoffersanauxiliaryinputwhichcanbe
set to carry out one of the following 6 functions:
- Partial opening type 1: this carries out the same function as the STEP-
BY-STEP input. It causes only the upper leaf to open. It only works if the gate
is closed completely, otherwise the command is interpreted as if it were a
STEP-BY-STEP comman.
- Partial opening type 2: this carries out the same function as the STEP-
BY-STEP input. It causes the two leafs to open for half the time it would take
them to open completely. It only works if the gate is closed completely, oth-
erwise the command is interpreted as if it were a STEP-BY-STEP command.
- Open only: this input only causes opening in the Open-Stop-Open-Stop
sequence.
- Close only: this input only causes closing in the Open-Stop-Open-Stop
sequence.
- Photo 2: this carries out the function of the “PHOTO 2” safety device.
- Disabled: the input will not carry out any function
• Discharge time: At the end of the Closing manoeuvre, after the leafs have
reached the totally closed position, the motor continues to “push” the leaf for
a brief interval, to ensure perfect closure. Immediately afterwards, this func-
tion activates a very brief inversion of movement to reduce excessive pres-
sure exerted by the motor on the leafs.
• Current sensitivity: Thecontrolunitisequippedwithasystemwhichmeas-
ures the current absorbed by the two motors used to detect the mechan-
ical stops and any obstacles when the gate is moving. Since the current
ab sorbed depends on a number of conditions, including the weight of the
gate, friction, wind and variations in voltage, the cut-in threshold can be
changed.Thereare6levels:1isthemostsensitive(minimumforce),6isthe
leastsensitive(maximumforce).
By increasing the amperometric sensitivity level the deceleration speed
increases during the closing phase of the manoeuvre.
WARNING! – If the “current sensitivity” function (together with other
vital features) is adjusted correctly, the system will comply with Euro-
pean standards, EN 12453 and EN 12445, which require techniques or
devices to be used to limit force and danger during the functioning of
automatic gates and doors are moved.
• Leaf delay: Thedelayinstartingupthemotorofthelowerleafcanbepro-
grammedto5,10,20,30or40%oftheworkingtime.
5.3 - Programming
Allthefunctionsdescribedinparagraph5.2“Programmablefunctions”chap-
ter can be selected by means of a programming phase which terminates by
memorisingthechoicesmade.Thecontrolunitthereforehasamemorywhich
stores the functions and parameters relative to the automation process.
TheP1,P2andP3buttonsareusedforalltheprogrammingphases,whilethe
5LEDs(L1,L2…L5)indicatetheselectedparameter.
Therearetwodifferentprogramminglevels:
• At level 1,thefunctionscanbeenabledordisabled.EachLed(L1,L2…L5)
correspondstoafunction:iftheLedison,thefunctionisactive;ifitisoff,it
is deactivated.
Leveloneconsistsin2partswhichcanbeselectedusingtheP3button.The
cor responding LED P3 indicates which of the 2 parts has been selected.
Level one (P1 Led lit): part two (P3 Led lit)
L1Led L2Led L3Led L4Led L5Led
Everything in Electric lock Resistance Heavy gates Gate open
stand by / stop proportional
Phototest
Level one (P1 Led lit): part one ( P3 Led off)
L1Led L2Led L3Led L4Led L5Led
Closing Function Pre-ash Close after Delay in
Automatic Condominium photo opening
• It is possible to pass to the second level from level one of part one. At this
second level the user can choose the parameter relating to the function. A
different value corresponds to each LED which must be associated to the
parameter.
Level one (P1 Led lit): part two (P3 Led lit)
L1Led L2Led L3Led L4Led L5Led
Everything in Electric lock Resistance Heavy gates Gate open
stand by / stop proportional
Phototest
Level one (P1 Led lit): part one (led P3 off)
L1Led L2Led L3Led L4Led L5Led
Closing Function Pre-ashing Close after Delay in
automatic condominium photo opening
Level two:
Parameter: Parameter: Parameter: Parameter: Parameter:
Time AUX input Time Current Leaf delay
pause discharge sensitivity
L1:5s L1:Open L1:no L1:Level1 L1:5%s
partialTYPE1 discharge (moresensitive)
L2:10s L2:Open L2:0.3s L2:Level2 L2:10%
partialTYPE2
L3:20s L3:OpenOnly L3:0.7s L3:Level3 L3:20%
L4:40s L4:CloseOnly L4:1.3s L4:Level4 L4:30%
L5:80s L5:Photo2 L5:2s L5:Level5 L5:40%
(lesssensitive)
All LEDs off: All LEDs off:
input Level 6
not used (max current
sensitività)
EN