64 – ENGLISH
Speed management (0x40)
Open speed (25
4
100 (%), default = 60%)
The function can be used to programme the motor speed during an opening manoeuvre.
Opening slowdown speed (22
4
100 (%), default = 22%)
The function can be used to programme the motor speed during the slowdown phase of an opening manoeuvre.
Close speed (25
4
100 (%), default = 60%)
The function can be used to programme the motor speed during a closing manoeuvre.
Closing slowdown speed (22
4
100 (%), default = 22%)
The function can be used to programme the motor speed during the slowdown phase of a closing manoeuvre.
Surge (0x8F)
Active (ON
4
OFF, default = OFF)
This function is useful in the presence of high static friction (for example, snow or ice obstructing the automation) as it allows for momentarily increasing
(see surge time) the speed and force used in the initial phase of a manoeuvre
Function ON = the values assigned to the functions associated with motor force and speed are (momentarily) increased to give the motor more power
during the initial phase of a manoeuvre
Function OFF = normal operation
Surge time (0
4
10 (s), default = 0s)
This function can be used to programme the duration of the motor’s initial surge
a
WARNING! The function is only effective if the “spurge” function is set to ON.