22 – ENGLISH
5.3.2 LEAF LENGTH LEARNING OPERATIONS
Before proceeding, make sure that the gate leaf is positioned midway
along its path (not completely closed nor completely open). If it is not,
unlock the motor, move the leaf then lock the motor again.
– Press and hold buttons
g
and
h
– Release the buttons when the manoeuvre starts (after approx. 3 sec-
onds)
– Verify that the current manoeuvre is a closing movement, otherwise
press the
g
button and check the procedures described in
“Figures 19, 20, 21, 22, 26 and 27” with greater care
– Wait for the control unit to fully complete the gate closing manoeuvre up
to the closing limit switch; the opening manoeuvre will start immediately
afterwards once the opening limit switch is reached
– Wait for the control unit to complete the opening manoeuvre
– Wait for the control unit to complete the nal closing manoeuvre.
12V OSE
Bluebus
Aerial
42
This procedure ensures rapid programming of the opening and closing po-
sitions, leaving the control unit to automatically calculate the intermediate
positions which can be modied later on through the “myNice Pro” app
and the compatible interfaces.
If the procedure was successful, LEDs "L3" and "L4" will switch off.
43
m
Warning! The position programming procedure (made
through the control unit buttons) is automatic. If the pro-
cedure is interrupted, it must be resumed from the be-
ginning.