ENGLISH – 65
Pre-ashing (0x93)
– Active (ON
4
OFF, default = OFF)
This function can be used to generate a pre-ash before the start of each manoeuvre to signal in advance a danger situation. The pre-ashing times can
be congured for each manoeuvre direction
Function ON = activate the pre-ashing time between activation of the warning light and the start of an opening or closing manoeuvre
Function OFF = the warning light starts ashing when the manoeuvre starts
– Opening time (1
4
10 (s), default = 3s)
This function can be used to programme the ashing time that signals the imminent start of an opening manoeuvre; it is associated with the “pre-ash
-
ing” function.
– Closing time (1
4
10 (s), default = 3s)
This function can be used to programme the ashing time that signals the imminent start of the closing manoeuvre; it is associated with the “pre-ashing”
function.
Stand-by (0x8B)
– Active (ON
4
OFF, default = OFF)
This function can be used to reduce electrical consumption to the maximum as, after the “stand-by time” at the end of each manoeuvre, the outputs,
internal peripherals and status LEDs will be switched off.
Function ON = Activates the stand-by function according to the prole chosen on “Mode”. This function is particularly useful in case of battery-powered
operation
Function OFF = normal operation of the automation
– Mode (safety devices
4
BlueBus
4
all, all except Wi-Fi, default = safety devices)
The stand-by function has 4 operating modes:
– safety devices – The control unit switches off the BlueBus photocell transmitters and all LEDs, except for the BlueBus LED, which will ash
more slowly instead.
– BlueBus – The control unit switches off the BlueBus output (the devices) and all LEDs, except for the BlueBus LED, which will ash more
slowly instead.
– all – The control unit switches off: the BlueBus output (the devices), the control unit outputs (and the outputs of any expansion modules), the
12 V services voltage, the Wi-Fi module (where present) and all the LEDs, except for the BlueBus LED which will ash more slowly instead.
– all except Wi-Fi – The control unit switches off: the BlueBus output (the devices), the control unit outputs (and the outputs of any expansion
modules), the 12 V services voltage, and all the LEDs, except for the BlueBus LED which will instead ash more slowly. In this mode, the
integrated Wi-Fi module is not switched off!.
a
WARNING! When the control unit receives any movement command, it restores normal operation. At the end of the manoeu-
vre, if the function is ON, the control unit will reactivate the Stand-by mode.
– Stand-by time (5
4
250 (s), default = 60s)
This function can be used to programme the time between the end of a manoeuvre and the start of the “stand-by” function.
– MASTER SLAVE mode
The function all and all excluding Wi-Fi on the slave is inhibited despite LED “L4” indicating that this mode is active (see “Wiring diagram” paragraph
or table “Table 18”)
Automation lock (ON 4 OFF, default = OFF) (0x9A)
This function can be used to inhibit the automation’s movements.
Function ON = no type of sent command will be performed, with the exception of “High-priority step-by-step”, “Unlock”, “Unlock and close” and
“Unlock and open” commands.
Function OFF = normal operation