66 – ENGLISH
Button lock (ON 4 OFF, default = OFF) (0x9C)
This function disables operation of the buttons present on the control unit. This function is particularly useful if children are present
Function ON = the control unit inhibits any command sent from the control unit buttons
Function OFF = normal operation
a
Warning! The Radio button remains active
Internal radio inhibition (ON
4 OFF, default = OFF) (0x9B)
This function can be used to inhibit the operation of the internal radio. This function is particularly useful when using an external receiver with SM con
-
nector (optional accessories) belonging to the OXI, OXIBD, etc. families.
Function ON = disables the operation of the internal receiver
Function OFF = normal operation (integrated radio enabled)
Brief reversal value (0,5 4 5 (s), default = 3 (s)) (0x31)
This function can be used to programme the duration of the brief reversal time that the control unit commands as a safety manoeuvre after an obstacle
is detected or a “Stop” command is sent.
Maximum Work Time (10 4 250 (s), default = 120 (s)) (0xA7)
This function can be used to dene the maximum duration allotted to each manoeuvre. Once this time has elapsed, the control unit performs a STOP
automatically by stopping the current manoeuvre. This function is particularly useful for safeguarding the integrity of the electrical motor.
Electric lock time (0,1 4 10 (s), default = 2 (s)) (0x5A)
This parameter can be used to programme in the control unit the desired time that must elapse between the end of a closing manoeuvre and the start
of an opening manoeuvre.
Suction cup time (0,1 4 10 (s), default = 2 (s)) (0x5C)
This parameter can be used to programme in the control unit the desired time that must elapse between the end of a closing manoeuvre and the start
of an opening manoeuvre, when the suction cup is detached.
Courtesy light time (0 4 240 (s), default = 60 (s)) (0x5B)
This parameter can be used to programme the desired duration for which the courtesy light remains lit at the end of each manoeuvre or following a
“Courtesy light timer” command
Functions that can be programmed using the Oview programmer
Slave mode:
This parameter is an ON / OFF type parameter; the factory setting is “OFF”. If there are two gearmotors that must operate in a synchronised manner,
each installed on one of the two leaves of a gate or door, one must function as the primary (Master) gearmotor and the other as the secondary (Slave)
gearmotor. To congure the system in this way, set the Master motor to “OFF” and the Slave motor to “ON”.