7210 SAS-M, T, R6, R12, Mxp, Sx, S Basic System
Configuration Guide
System Management
3HE 17358 AAAB TQZZA © 2021 Nokia.
Use subject to Terms available at: www.nokia.com
679
Description Commands in this context clear script information.
script-policy
Syntax script-policy
Context clear>system>script-control
Platforms Supported on all 7210 SAS platforms as described in this document, including platforms
configured in the access-uplink operating mode
Description Commands in this context clear script policy information.
completed
Syntax completed [script-policy-name] [owner owner-name]
Context clear>system>script-control>script-policy
Platforms Supported on all 7210 SAS platforms as described in this document, including platforms
configured in the access-uplink operating mode
Description This command clears completed script run history entries.
Parameters script-policy-name — Clears history entries only for the specified script-policy.
owner-name — Clears history entries only for script-policies with the specified owner.
Default “TiMOS CLI”
sync-if-timing
Syntax sync-if-timing {ref1 | ref2 | bits1 | bits2}
Context clear>system
Platforms Supported on all 7210 SAS platforms as described in this document, including platforms
configured in the access-uplink operating mode; not supported on platforms configured in the
standalone-VC operating mode
Description This command individually clears (re-enable) a previously failed reference. As long as the
reference is one of the valid options, this command is always executed. An inherent behavior
enables the reverted mode which causes a re-evaluation of all available references.
Parameters ref1 — Clears the first timing reference.
ref2 — Clears the second timing reference.