Ambient Light Sensor calibration
Functionality check
Steps
1. Connect the phone to
Phoenix
, start the
Phoenix
software, and set the phone (e.g. on the table) so that
the ambient light visible to ALS is stable. The light quide of the ALS is located on the upper part of the
phone’s front cover, right next to the secondary camera.
2. Scan product on Phoenix (CTRL+R)
3. Choose TestingDisplay test.
4. Open the Lights tab, and check the Ambient light sensor check box. Click the Read button in order to get
the reference ambient light value. Cover the sensor and click Read again. When covered, the luminance
reading should be less than after clicking Read without covering the sensor.
5. If the component does not give any reading or the reading does not change when sensor is/is not covered,
replace the part.
Note: In RM-356 the ALS module is located on the UI flex assembly. ALS calibration must always be
done when the UI flex assembly is changed. Also, if the ALS calibration values are lost from the phone,
ALS needs to be recalibrated.
The ALS calibration procedure requires a reference phone with a calibrated ALS.
RM-356
BB Troubleshooting and Manual Tuning Guide
Issue 1 COMPANY CONFIDENTIAL Page 3 –39