EasyManuals Logo

Nord Drivesystems SK 200E Series User Manual

Nord Drivesystems SK 200E Series
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
POSICON positioning control Supplementary manual for series SK 200E and SK 250E-FDS
18 BU 0210 en-3117
Pos: 54 /A nl eitu nge n/El ek tro nik/FU u nd S tart er/ 2. M o ntag e un d Ins tall ation/M ont age/FD S [SK x xxE-FDS ]/ Auss tatt ungs var ia nte n_04 _Ko nfig ur ati on d er O pti onspl ätz e der A nst euer ung seb ene _01 [SK 2 xxE-FD S] @ 12\ mod_1467125723781_388.docx @ 334298 @ 5 @ 1
Configuration of option slots on the control level
The option slots M1 to M8 are designed for M12 plug connectors. The configuration of the connections
or functions for the individual option slots which are relevant for the frequency inverter is printed
directly on the option slot.
Option slot Option type
Function Relevant
parameters
Comments
M1 a No option
b
Initiator 1
INI1
DIN1
P420[-01]
Not available if M5
c has zero track.
Set the function of
the zero track in
P420[-01].
DIN4
P420[-04]
M2
a
No option
b
Initiator 2
INI2
DIN4
P420[-04]
M3
a
No option
b
Actuator 1
Act1
DOUT1
P434[-01]
DOUT2 P434[-02]
M4
a
No option
b
Actuator 2
Act2
DOUT2
P434[-02]
M5
a
No option
b
Initiator 3
INI3
DIN2
P420[-02]
DIN3 P420[-03]
c
HTL encoder
1)
HTL
DIN2
P420[-02]
DIN3 P420[-03]
d
System bus master
SYSM
M6
a
No option
b Initiator 4 INI4 DIN3 P420[-03] only SK 250E-FDS /
SK 270E-FDS
c
Safe Stop
STO
only SK 260E-FDS /
SK 280E-FDS
M7
a
No option
b Initiator 5 INI5 AIN1 /
DIN6
P400[-01] /
P420[-06], P113
H1 / H2 only usable
to a limited extent
AIN2 /
DIN7
P400[-02] /
P420[-07], P113
c
System bus slave or
absolute encoder
SYSS
M8 a No option
b
Initiator 6
INI6
AIN2 /
DIN7
P400[-02] /
P420[-07], P113
only SK 250E-FDS /
SK 260E-FDS,
H1 / H2 only usable
to a limited extent
c
24 V DC supply
2)
24VI
d
AS interface AUX
AUX
only SK 270E-FDS /
SK 280E-FDS
e AS interface ASI
1)
Encoder cable available on request If the encoder has a zero track, evaluation of the zero track is only via DIN1.
2)
The DC control voltage can also be supplied via M8 c (AUX) or the option slots X1 or Z1 Z4 of the connection level.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nord Drivesystems SK 200E Series and is the answer not in the manual?

Nord Drivesystems SK 200E Series Specifications

General IconGeneral
BrandNord Drivesystems
ModelSK 200E Series
CategoryInverter
LanguageEnglish

Related product manuals