46
SET NORM SAFETY STOP
information includes (Fig. 38):
> Graphic SAFE
> Symbols STOP and TIME.
> Safety Stop Time Set Point, flashing.
> Safety Stop Depth Set Point and symbol FT (or M).
 Pressing and releasing the S button momentarily (< 2 seconds each) will step through
the Stop T ime Set Points of OFF, 3:00, and 5:00 (minutes:seconds).
 Pressing and releasing the A button momentarily (< 2 seconds) will save the Stop T im e
setting and the Stop Depth Set Point will flash, or if Stop T ime is set OFF advance to
the SET CONS (Conservative Factor) screen with the Set Point flashing.
 Pressing and releasing the S button momentarily (< 2 seconds each) will step through
the Stop Depth Set Points of 10, 15, and 20 FT (or 3, 4, 5, and 6 M).
 Pressing and releasing the A button momentarily (< 2 seconds) will save the Safety
Stop settings and/or advance to the SET CONS screen with the Set Point flashing.
 Pressing the A button repeatedly (< 2 seconds) will step through the other SET U
screens.
 Depressing the A and S buttons simultaneously for 2 seconds
will save the settings and revert to the SET U screen.
 Depressing the M button for 2 seconds or if no button is
pressed for a period of 2 minutes operation will revert to the
NORM or GAUG SURF MAIN screen.
Fig. 38 - Set Safety Stop

Table of Contents